Environmental Instruments

Gilson Automated GX-271 GPC Clean-up System

Automated GX-271 GPC Clean-up System

Automate post-extraction clean-up of interfering substances from environmental samples, food products and animal tissue by Gel Permeation Chromatography (GPC) prior to analysis by GC, GC/MS, HPLC or LC/MS. Failure to remove these interfering compounds can cause poor analytical results, shorten column life and increase analytical downtime.

The Automated GX-271 GPC Clean-up System provides an affordable solution for laboratories performing residue analysis of complex matrices such as fatty foods, soils, sludge, animal and plant tissue.

The system features a Direct Injection Module and a fraction collection valve located on the Z-arm, increasing efficiency by reducing sample carryover and post valve dead volume.
The Automated GPC system is controlled with TRILUTION® LC Software, a user-friendly, easy-to-use, flexible program that was specifically designed to meet the laboratory needs. The software features pre-programmed methods specific to GPC post-extraction clean-up processes.
Gilson GPC Clean-up Systems meet clean-up guidelines set forth by the USEPA, USFDA, USDA, USGS, ISO, CFIA, AOAC International and European Union (EN 1528, EN 12393, S19) requirements.


Specifications

  • Pump Reciprocating pump with single-piston interchangeable head, constant stroke and fast refill motion, internal pulse dampener and pressure feedback
  • Accuracy < ± 1%
  • Repeatability < 1%
  • Flow Rate 10 uL/min to 10 mL/min
  • Dimensions (w x d x h)  33 x 33 x 15 cm (13 x 13 x 6 in)
  • Maximum Pressure 4000 psi (276 bar)
  • Injection Volume GX-271 Liquid Handler/Injector: 20 uL to 5 mL (5 mL standard)
  • Vertical Punch Strength 3.2 kg (7 lb) for septum piercing Syringe Pump  402 Single Syringe Pump with 10 mL syringe
  • Sample Rack Capacity Options 13 x 100 mm tubes, 16 x 100 mm tubes and other options available upon requestCollection Rack Capacity Options  25 x 200 mm tubes, 38 x 200 mm tubes, 125 mL or 250 mL Boston Round Bottles, Caliper TurboVap™ Evaporation Tubes (50 and 200 mL, Labconco RapidVap Evaporation Vessels (100 mL flat, 450 mL flat or with stem), 125 mL and 250 mL flasks for rotary evaporation and other options available upon request.
  • UV Detector Wavelengths at 254nm or 280 nm with 40 uL Flow Cell (10 mm path length)
  • Software Control  Computer control via Ethernet communication and TRILUTION® LC Software
  • GPC Clean-up Columns Compatible with various GPC Clean-up columns from low pressure glass to high pressure stainless steel
  • Optional GPC System Organizer Dimensions (w x d x h)  39.2 x 37.9 x 93.7 cm (15.5 x 14.9 x 36.9 in)
  • Environmental Conditions For indoor use only
  • Altitude: 2000 m
  • Temperature: 5ºC - 40ºC
  • Air pressure: 75 - 105 kPa
  • Pollution degree: 1 or 2, in accordance with IEC 66
  • Humidity: Maximum relative humidity 80% for temperatures up to 31º C, decreasing linearly to 50% relative humidity at 40ºC
  • Manufacturing Standards  Meets applicable safety and EMC certification standards; UL and CE certified
  • Fuse 5 x 20 mm “T” type 2.50A. One for 100 - 120V; two for 220 - 240V
  • Power Requirement  Frequency: 50 - 60 Hz
  • Voltage: 100 - 240V (universal input)
  • Current rating: 2.0A for 100 - 120V or 1.0A for 220 - 240V
  • Dimensions (w x d x h) 59.7 x 54.1 x 57.1 cm (23.5 x 21.3 x 22.5 in)
    Note: This does not include the 402 Single Syringe Pump



Produktgruppe

Pharmaceutical

Environmental

HPLC Systems

Instruments

Kontakt

Biolab A/S
Sindalsvej 29
8240 Risskkov
Telefon: 86 21 28 66
E-mail: sales@biolab.dk